RFID based on 13.56MHz
Xirgo Global devices support RFID readers, working based on 1Wire or Wiegand26 communication protocol.
This equipment is supported by following devices of FMS series: Light, Light+, StCAN, Tacho, XtCAN.
I. Operating with RFID Reader via 1Wire.
a) Physical connection.
Connect Reader as in schematics below:
Connect white wire and green wire of RFID Reader to 1Wire interface of device (brown wire). Black wire - connect to Ground. Red - to Plus.
b) Configuration.
To configure device to work with external equipment, need to make adjustments in the settings.
It is Logic template of regular devices, or Setting template in case of SDK line of devices.
Example of configuration for iButton functionality can be found in following links.
Regular devices: iButton configuration for logic template.
SDK devices: iButton configuration for Setting template.
c) Displaying in Monitoring platform.
ID, read from RFID, will come in dallas_id parameter for regular devices, or in sensor20480 for SDK devices.
II. Operating with RFID Reader via Wiegand26.
a) Physical connection.
Connect Reader as in schematics below:
Connect white wire of RFID Reader (Data0) to IN2 of device, green (Data1) - to IN3 of device. Black wire - connect to Ground. Red - to Plus.
b) Configuration.
To configure device to work with external equipment, need to make adjustments in the settings.
It is Logic template of regular devices, or Setting template in case of SDK line of devices.
Example of configuration for Wiegand26 can be found in following links.
Regular devices: Wiegand26 configuration for logic template.
SDK devices: Wiegand26 configuration for Setting template.
c) Displaying in Monitoring platform.
ID, read from RFID, will come in wie parameter for regular devices, or in sensor16481 for SDK devices.