Thermograph
Thermographs of refrigeration systems are supported by FMS500 Tacho and XtCAN devices.
Standard Xirgo Global devices supports following models: DataCold 600, Transcan-2, Thermoking Touchprint.
SDK device series can support more different models, but integration is made by requests.
a) Physical connection.
Device should be connected to Thermograph as described in schematics below:
RX wire of device goes to TX of thermograph, TX of device - to RX of thermograph. Also ground wire of thermograph should be connected to ground.
b) Adjustments in Logic Template.
To configure device to work with external equipment, need to make adjustments in Logic template, assigned to your device.
Example of configuration: Thermograph configuration.
c) Displaying in Monitoring platform.
Thermograph sends following information: real time temperature from sensors, digital status (doors and etc).
Parameters on monitoring platform are following: dataColdSens1, dataColdSens2, dataColdSens3, dataColdSens4, dataColdSens5, dataColdSens6, dataColdDig1, dataColdDig2, dataColdDig3, dataColdDig4, dataColdDig5, dataColdDig6, dataReserved.
Note. To get temperatures in celsius, muliply value to 0.1 and substract 273.