image-20250609-050823.png

 

Sentrius BT510 multi-sensor reports temperature, accelerometer, proximity and open/close switch data, it uses BLE and is supported only on LX40 series.

LX40 Series

  • LX41

  • LX42

  • LX43

  • LX44

  • LX45

 

 


1. Adjustments in Configuration

1.1. Adding Script

In configuration template ‘Script'->’Script1'->'Script' select ‘[BLE] Accessory Scanner V1.0’ script. When script is added script settings will appear below

image-20250609-052908.png

1.2. Configuring Script Filters

In newly appeared settings ‘Script1@[BLE] Accessory Scanner V1.0’ select ‘Filter' section and click import presets.

image-20250609-052955.png

In pop-up window select “Laird Sentrius BT510” and all presets will be filled out.

image-20250609-053146.png
image-20250609-053221.png

Under all added filters for temperature, magnet state, battery voltage, reset reason and flags in section 'Filter' add MAC address of the sensor, it should be visible on the back side of sensor.

image-20250609-053449.png

It is important to notice that when setting multiple sensors all their default sensor values will be the same. When adding multiple sensors manually change 'Sensor' parameter under each section.

image-20250609-053924.png

 


1.3. Displaying in Monitoring Platform

For more in depth configuration of device configuration visit Quick Set Up Of Configuration

For device to report sensor values to telemetry platform sensor values needs to be included into telemetry payload.

image-20250609-053644.png

2. Sentrius BT510 Documentation