ASAIR CM2305
1-Wire sensors is supported on Xirgo Global devices with 1-Wire communication.
XG37 Series
Light
Light+
XtCAN
Tacho
LX40 Series
LX42
LX43
LX44
LX45
1. Physical Connection
It is important to notice that CM2305 needs to be ordered from supplier with Molex-Pico 1.5mm 3pin connector to able to plug into available slot on XG device
Following XG output connector will be used for this sensor. This connector supplies 5V output up to 50mA.
2. Adjustments in Configuration
To configure device to work with CM2035 temperature sensors in XDM configuration template under ‘Hardware'->’1-wire'->'1-wire settings' select ‘1-wire function' to 'CM2305 sensor’
3. Displaying in Monitoring Platform
For more in depth configuration of device configuration visit Quick Set Up Of Configuration
To configure device to send 1-wire temperature sensors parameters to telemetry server following sensors needs to be added to payload:
SENSOR_OW_HUMIDITY (12360)
SENSOR_TEMPERATURE_1 (40983)
4. ASAIR CM2305 Documentation
Official documentation containing technical specifications of ASAIR CM2305 sensor.