1-WIRE Sensors
1-Wire sensors is supported on Xirgo Global devices with 1-Wire communication.
XG37 Series
Light
Light+
XtCAN
Tacho
LX40 Series
LX42
LX43
LX44
LX45
1. Operating with Single Temperature Sensor
1.1. Physical Connection
It is important to notice that not all 1-wire temperature sensors can feed from “parasite power“, check with temperature sensor supplier.
Connect Black and Red wires - to Ground, Yellow - to 1 Wire.
1.2. Adjustments in Configuration
To configure device to work with 1-wire temperature sensors in XDM configuration template under ‘Hardware'->’1-wire'->'1-wire settings' select ‘1-wire function' to 'ID ant temperature read’
1.3. Displaying in Monitoring Platform
For more in depth configuration of device configuration visit Quick Set Up Of Configuration
To configure device to send 1-wire temperature sensors parameters to telemetry server following sensors needs to be added to payload:
SENSOR_TEMPERATURE_ID_1 (20484)
SENSOR_TEMPERATURE_1 (40983)
2. Operating with Multiple Temperature Sensors
Up to 4 Temperature sensors can be connected at once.
2.1. Physical Connection
It is important to notice that not all 1-wire temperature sensors can feed from “parasite power“, check with temperature sensor supplier.
Connect Black and Red wires - to Ground, Yellow - to 1 Wire.
2.2. Adjustments in Configuration
To configure device to work with 1-wire temperature sensors in XDM configuration template under ‘Hardware'->’1-wire'->'1-wire settings' select ‘1-wire function' to 'ID ant temperature read’
2.3. Displaying in Monitoring Platform
For more in depth configuration of device configuration visit Quick Set Up Of Configuration
To configure device to send 1-wire temperature sensors parameters to telemetry server following sensors needs to be added to payload:
SENSOR_TEMPERATURE_ID_1 (20484)
SENSOR_TEMPERATURE_1 (40983)
SENSOR_TEMPERATURE_ID_2 (20485)
SENSOR_TEMPERATURE_2 (40984)
SENSOR_TEMPERATURE_ID_3 (20486)
SENSOR_TEMPERATURE_3 (40985)
SENSOR_TEMPERATURE_ID_4 (20487)
SENSOR_TEMPERATURE_4 (40986)