1-WIRE Sensors

1-WIRE Sensors

image-20250526-144713.png

 

1-Wire sensors is supported on Xirgo Global devices with 1-Wire communication.

XG37 Series

  • Light

  • Light+

  • XtCAN

  • Tacho

LX40 Series

  • LX42

  • LX43

  • LX44

  • LX45


1. Operating with Single Temperature Sensor

1.1. Physical Connection

It is important to notice that not all 1-wire temperature sensors can feed from “parasite power“, check with temperature sensor supplier.

Connect Black and Red wires - to Ground, Yellow - to 1 Wire.

image-20250521-130120.png
image-20250521-130137.png
image-20250521-103304.png
image-20250521-130202.png

1.2. Adjustments in Configuration

To configure device to work with 1-wire temperature sensors in XDM configuration template under ‘Hardware'->’1-wire'->'1-wire settings' select ‘1-wire function' to 'ID ant temperature read’

image-20250527-113606.png

1.3. Displaying in Monitoring Platform

For more in depth configuration of device configuration visit Quick Set Up Of Configuration

To configure device to send 1-wire temperature sensors parameters to telemetry server following sensors needs to be added to payload:

  • SENSOR_TEMPERATURE_ID_1 (20484)

  • SENSOR_TEMPERATURE_1 (40983)

image-20250521-132129.png

2. Operating with Multiple Temperature Sensors

Up to 4 Temperature sensors can be connected at once.

2.1. Physical Connection

It is important to notice that not all 1-wire temperature sensors can feed from “parasite power“, check with temperature sensor supplier.

Connect Black and Red wires - to Ground, Yellow - to 1 Wire.

image-20250521-130730.png
image-20250521-130748.png
image-20250521-105215.png
image-20250521-130812.png

2.2. Adjustments in Configuration

To configure device to work with 1-wire temperature sensors in XDM configuration template under ‘Hardware'->’1-wire'->'1-wire settings' select ‘1-wire function' to 'ID ant temperature read’

image-20250521-131112.png

2.3. Displaying in Monitoring Platform

For more in depth configuration of device configuration visit Quick Set Up Of Configuration

To configure device to send 1-wire temperature sensors parameters to telemetry server following sensors needs to be added to payload:

  • SENSOR_TEMPERATURE_ID_1 (20484)

  • SENSOR_TEMPERATURE_1 (40983)

  • SENSOR_TEMPERATURE_ID_2 (20485)

  • SENSOR_TEMPERATURE_2 (40984)

  • SENSOR_TEMPERATURE_ID_3 (20486)

  • SENSOR_TEMPERATURE_3 (40985)

  • SENSOR_TEMPERATURE_ID_4 (20487)

  • SENSOR_TEMPERATURE_4 (40986)

image-20250521-132355.png