ELA RHT

ELA RHT

image-20250526-142848.png

 

ELA RHT temperature and humidity sensor uses BLE and is supported only on LX40 series.

LX40 Series

  • LX41

  • LX42

  • LX43

  • LX44

  • LX45

 

 


1. Adjustments In Configuration

1.1. Adding Script

In configuration template ‘Script'->’Script1'->'Script' select ‘[BLE] ELA RHT V1.0’ script. When script is added script settings will appear below

image-20250526-142953.png

1.2. Configuring Script Peripheral Settings

In ‘Filter type’ select ‘Name filter' fill out device name as written on ELA RHT device, for example - 'P RHT 900459'.

For ‘Temperature sensor’, ‘RSSI’ select desired sensors where values will be saved, take note of selected sensors.

For this example we choose:
Temperature sensor - sensor 40963
RSSI - sensor 24576
Humidity sensor - sensor 12301

image-20250526-143216.png

1.3. Displaying in Monitoring Platform

For more in depth configuration of device configuration visit Quick Set Up Of Configuration

For device to report sensor values to telemetry platform sensor values needs to be included into telemetry payload.

image-20250526-143536.png

2. ELA RHT Documentation

Official documentation containing technical specifications, calibration and configuration info of ELA RHT temperature and humidity sensor.