Functions

Functions



No.

Function

Value

Description

No.

Function

Value

Description

1.2

GpsPower

ON/OFF

Controls GPS receiver power.

2.1

InternetConnection

Ban/Permit/Force disconnect

Controls device connection to internet (PDP context).
Note. When selected "Ban", device does not interrupt current session until network provider close it. If you want device to terminate the connection, you must pick "force disconnect".

2.2

ServerConnection

Disconnect/Connect/FMSet disabled, server enabled

Controls device connection to server.
Note. Device connects to data server and to configuration server separately. If you want to disconnect device from configuration server to save GPRS traffic, select option FMSet disabled, server enabled.

2.3

DataSendPeriod

Value in seconds
Min = 0
Max = 570

Period for data sending to server.
If set to 0 - time is controlled by server.
Note. This function is not responsible for data collection into internal flash.

2.4

DataSendOnInputsChange

IN1-IN15

Checkbox selection

Inputs set. If selected - will force data sending to server depending on preferred inputs change.
Note. Data send will trigger on any change: from 0 to 1 and/or from 1 to 0.

2.5

BroadcastMessagePeriod

Value in seconds

Min = 0
Max = 570

Data messages without confirmation.
This method can be used when frequent data sending is necessary.
Note. Using this mode, data is not saved into internal flash. If unit looses GSM/GPRS connectivity, history will be lost.

3.1

GpsQualityMaxHdop

Value in relative units

Min = 0,8
Max = 10

Internal GNSS filter. Maximum HDOP value to accept it to read.
HDOP - Horizontal delusion of precision.
Recommended value - 3,5.

3.2

GpsQualityMinSat

Value in satellite count

Min = 3
Max = 30

Internal GNSS filter. Minimum satellites quantity to accept to read it.

3.3

GpsReadPeriod

Value in seconds

Min = 0
Max = 3600

Internal GNSS filter. Period for reading coordinates from GNSS receiver.

3.4

MaxTimeBetweenTwoGpsPoints

Value in seconds

Min = 0
Max = 21600

Data collection timeout.

Function is responsible for record registering into internal flash

3.5

GpsCourseChangeFix

Value in degrees

Min = 0
Max = 360

Data collection on course change.

Function is responsible for record registering into internal flash.

3.6

GpsSpeedChangeFix

Value in Kilometer per hour

Min = 5
Max = 100

Data collection on speed change.

Function is responsible for record registering into internal flash.

3.7

InputsChangeFix

IN1-IN15

Checkbox selection

Data collection on input change.

Function is responsible for record registering into internal flash.

3.8

MaxDisatanceBetweenTwoGpsPoints

Value in meters

Min = 0
Max = 65536

Data collection on distance change.

Function is responsible for record registering into internal flash.



4.1

Dataset7_Mask1

-

Set of parameters included to the packet.

For detailed parameter descriptions please refer to section Parameter Description Table.

4.2

Dataset7_Mask2

-

Set of parameters included to the packet.

For detailed parameter descriptions please refer to section Parameter Description Table.

4.3

Dataset7_Mask3

-

Set of parameters included to the packet.

For detailed parameter descriptions please refer to section Parameter Description Table.

4.4

Dataset7_Mask4

-

Set of parameters included to the packet.

For detailed parameter descriptions please refer to section Parameter Description Table.

4.5

Dataset7_Mask5

-

Set of parameters included to the packet.

For detailed parameter descriptions please refer to section Parameter Description Table.

5.1a

GeneralBitConfig



Set of parameters, that controls/enables additional functionality. For detailed description please refer to section GeneralBitConfig.

5.1b

GeneralBitConfig2



Set of parameters, that controls/enables additional functionality. For detailed description please refer to section GeneralBitConfig.

5.2

VibrationThreshold



Accelerometer control function to detect motion signal (related to virtual input - IN1).

Note. Function is used only for old generation hardware (5.0 - 5.4 versions). For all newer versions, optimal threshold is selected and cannot be changed.

5.3

NotDeliveredDataThreshold



Stack size threshold to generate signal stack size threshold reached.

Internal function, that monitors recorded messages count (in bytes) in flash memory.

5.4

IN8VoltageThreshold



IN8 virtual input voltage threshold.

Linked to main power supply (Vcc and GND wires).

5.5

IN6VoltageThreshold



IN6 virtual input voltage threshold.

Linked to analog input 3 (ADC3).

5.6

FrequencyCounterSelect



Control function for IN2-IN5 digital inputs.

a) If check-box empty - inputs work in frequency mode

b) If check-box selected - inputs work in impulse counter mode

5.7.1

CAN1FunctionSelect



Control function for CAN1 line

a) For device version older than FMS500, specific model and make must be selected

b) For FMS500 and newer version devices, CAN BASE B must be selected by default (model and make is selected within device settings)

Note. for trucks with standard FMS protocol, use old type settings (FMS J1939 selected directly in the logic template despite device version).

5.7.2

CAN2FunctionSelect



Control function for CAN2 line

a) Older than FMS500 series devices had only one CAN line

b) For FMS500 and newer version devices, CAN BASE B must be selected by default (model and make is selected within device settings)

Note. for trucks with standard FMS protocol, use old type settings (FMS J1939 selected directly in the logic template despite device version).

5.8

EIA485FunctionSelect



Control function for RS485 digital interface. For detailed description please refer to section RS485 Control.

5.9

RS232FunctionSelect



Control function for RS232 digital interface. For detailed description please refer to section RS485 Control.

5.a

NewConnectionsTointernetLimiter

Value = seconds

Next connection to internet (PDP context) timeout.

Restricts connection to internet for selected period of time.

5.b

Timer1



Internal timer to generate timer1 signal.

Date and time picker to select when timer signal should be active/inactive

5.c

Timer1_GMT



Time zone selection.

Linked to Timer1 function

5.d

Timer2_Control



Internal timer to generate timer2 signal.

Complex timer structure to create an internal delay.

5.e

Timer2_Threshold

Value = seconds

Timeout threshold.

Linked to timer2_Control function.

5.f

OUT1_Control



Control function for digital output (open collector type)

5.g

OUT2_Control



Control function for digital output (open collector type)

5.g

OUT3_Control



Control function for digital output (open collector type)

5.h

DigitalInputsThreshold

Value = Volts

Voltage threshold for digital inputs (IN2-IN5)

5.i

GPS_Speed_Threshold

Value = km/h

Speed threshold to generate signal GPS speed present

5.j

S1_Control



Control function to generate signal static signal 1

5.k

S2_Control



Control function to generate signal static signal 2

5.l

Data_Delivery_Watchdog

Value = seconds

Min = 120s

Max = 1200s

Device reset timeout.

If device cannot deliver data to server for more than X seconds, internal watchdog resets the unit.

X = timeout selected

5.ma

Timer3_Control



Internal timer to generate timer3 signal.

Complex timer structure to create an internal delay.

5.ma

Timer4_Control



Internal timer to generate timer4 signal.

Complex timer structure to create an internal delay.

5.na

Timer3_Threshold

Value = seconds

Timeout threshold.

Linked to timer3_Control function.

5.na

Timer4_Threshold

Value = seconds

Timeout threshold.

Linked to timer4_Control function.

5.o

1W_Function



1-Wire interface control function.

a) 1W constant read - Device is constantly requesting data from connected sensor

b) 1W constant read one ID - Device is requesting only one address

c) 1W constant read raw ID - Device is requesting one ID and sending to server its raw value

d) Output OFF/Sleep - 1-Wire interface disabled

e) Output ON - 1-Wire interface used as output

f) Convert ID V1 - special ID format response

g) Convert ID V2 - special ID format response

h) Convert ID V3 - special ID format response

i) 1W Constant read raw ID full raw - Device is constantly requesting data from connected sensor and sending raw value to server

5.p

Battery charge

Value = mA

Min = 50mA

Max = 1300mA

Internal battery charge function.

Charging current selection. Possible to increase charging current for bigger capacity batteries to reduce charging time.

Note. If no internal battery connected, charging function should be disabled.

6.1

Crash pulse length

Value = ms

Measurement period

6.2

G1 force start value

Value = G

Starting acceleration value of the impact

6.3

G2 force mean value

Value = G

Average acceleration value for the measurement period

6.4

Dataset4_Timeout

-

Reserved

6.5

Dataset51_Timeout

-

Reserved

6.6

Dataset8_Timeout

-

Reserved

6.7

Sms_TrigerMaskRising

-

Reserved

6.8

Sms_TrigerMask_Faling

-

Reserved

6.9

Sms_MextSmsTimeout

-

Reserved

6.a

Sms_MaxSmsPerHour

-

Reserved

6.b

AccelerationThreshold

Value = G

Acceleration threshold to generate "modem on" signal.

Acceleration value, calculated by internal accelerometer.

6.c

BrakingThreshold

Value = G

Braking threshold to generate "modem on" signal.

Braking value, calculated by internal accelerometer.