Conditions
States of conditions
Conditions can have 3 states:
Below is example of data send configuration. Meaning of configuration is: to send data every 30s when IN5 (Ignition) is active and send every 300s when IN5 is inactive.
Description of conditions
Condition or Parameter |
|
|
|---|---|---|
Reset | Reset of device happened | Reset of device did not happen |
Modem on * | Modem is On / Acceleration, Braking, Cornering threshold reached | Modem is Off / Acceleration, Braking, Cornering threshold not reached |
IN1 - motion | Motion or strong vibration is detected | No motion is detected |
IN6 | Any analog input (ADC) is active | All analog inputs are inactive |
Timer3Threshold | Threshold of Timer 3 is reached | Threshold of Timer 3 is not reached |
System time registered | N/A | N/A |
Geozone inside | Device detects being inside geozone | Device is outside geozones |
Poor GPS signal | GPS signal is weaker than described in 3.1 and 3.2 functions | GPS signal is strong |
GSM jamming | GSM jamming detected | No GSM jamming is detected |
Roaming | Device is in Roaming | Device is connected to home network |
GSM registered | Device is registered to GSM network | No GSM registration is detected |
GPRS registered | Device is registered to GPRS network | No GPRS registration is detected |
Internet active | Internet connection is active | No internet connection |
Preferred operator active | Operator from Preferred operators' list is active | No preferred operators to register |
GPS speed present | Speed threshold, set in 5.i function is reached | Speed is below 5.i function threshold |
Wiegand present | Wiegand26 key is detected | Wiegand key is not attached |
IN2 | Input 2 is active | Input 2 is not active |
IN3 | Input 3 is active | Input 3 is not active |
IN4 | Input 4 is active | Input 4 is not active |
IN5 | Input 5 is active | Input 5 is not active |
IN7 - engine on | Voltage above 13.2V or 26.6V is reached | Voltage is lower than running engine |
IN8 | Power supply is On | Power supply is absent |
One hour tick | Signal ON every one hour for 10 min period | Signal OFF every one hour for 10 min period |
Six hours tick? | Signal ON every six hours for 10 min period | Signal OFF every six hours for 10 min period |
Stack size threshold reached | Stack size of data, described in 5.3 is reached | Stack size is not reached |
Geozone inside geozone | Device detects being in 2 geozone at a time | Device is not in 2 geozones at a time |
Timer4Threshold | Threshold of Timer 4 is reached | Threshold of Timer 4 is not reached |
Static signal 1 | Static signal 1, configured in 5.j function is present | Static signal 1 is not present |
Static signal 2 | Static signal 2, configured in 5.k function is present | Static signal 2 is not present |
Timer1 | Current time is in a range of Timer 1 ON | Current time is in a range of Timer 1 OFF |
IbuttonPresent | iButton key is detected | iButton key is not attached |
Timer2Threshold | Threshold of Timer 2 is reached | Threshold of Timer 2 is not reached |
*- For new version devices parameter Modem on activates when acceleration, cornering or braking threshold values are reached.