Structure of Setting template

Structure of Setting template

During manufacturing every device receives a setting template with main functionality.

In XDM portal you can edit existing template, or create your own to create desired performance.

Note. For Setting template to work, you need to configure just few elements (APN, Telemetry server, Data packet), rest are optional.


Main tree of Setting template.

 

1. Connectivity.

This part controls all settings related to device connections to servers.

Category

Subcategory

Description

Category

Subcategory

Description

Configuration server

Session setting

Settings and rules for connecting to XDM configuration manager.

Server address

By default must be set to the following address:
Domain: devices.xgfleet.eu
Port: 1888
Protocol: TCP

Internet permissions

Connection permission settings

Allows to configure internet permissions, or bans in certain conditions (roaming, etc.)

GSM/GPRS

GSM operator group

Allows to assign a group of operators to ban them, or make as preferred

APN list

APN list is necessary for automatic activation and correct device behavior

SMS service number

Phone number of technical team to get replies from SMS commands to

Telemetry server

MQTT security

Settings of authorization, and encryption

MQTT broker address

Address where telemetry data will be sent

MQTT session parameters

Keep alive intervals, session time, etc.

MQTT topic names

Topic names to request data

NTP server

NTP server settings

Domain and enabling of NTP server


2. Hardware.

This part controls all peripherals of the unit (f.e. Outputs, 1-wire, CAN, GNSS).

Category

Subcategory

Description

Category

Subcategory

Description

Outputs

OUT settings

Set a way of output control - by script, or remote commands

Digital inputs threshold

Inputs threshold settings

Voltage, from which inputs will get On

GNSS

GNSS settings

Source, behavior and minimum quality requirements for GNSS

Wiegand26

Wiegand26 settings

Control of Wiegand interface

CAN

CAN function ID setting

Setting reading of CAN interface

Vehicle model

CAN program to read from CAN Database

1-wire

1-wire settings

Control of 1-Wire interface

LED

LED settings

Selecting a source of LED flashes

Battery charging

Battery charging settings

Current to charge internal battery


3. Data Recording.

This part controls parameter registration rules (which parameters will be included into packet).

Category

Description

Category

Description

Simple

Here you can create a data packets, which will be triggered from chosen conditions.

Extended

Here you can create sensors, which can trigger from chosen conditions, time, or threshold of sensor value.

Note. Simple and Extended options can not be used simultaneously. If you set both - device would not send any data.

Check more about differences and configuration here: Data recording methods.


4. Script.

This part is Script manager (assign already released script). Maximum scripts to be assigned is 3.

Here you can assign scripts, which you have created and released. Also scripts, created by Xirgo team. By default we provide for free LLS script to read fuel level sensors via RS232 or RS485 and Common script (to control outputs, timers, static signals, identification, speed, eco-driving and more).


5. Deep Sleep.

This part controls "sleep" mode of the unit (energy saving mode).

In chosen conditions device can go into sleep mode by disabling all interfaces and processes inside the device. It will let to reach consumption <8 mA.

More about configuration of this option: Sleep mode configuration.


6. Identification.

This part lets to assign already created ID lists to a template.

Later you can use it to create immobilization functionality with f.e. Common script.


7. Geofencing.

This part is geozone group manager (assign already imported geozone groups).

Later you can use it to create speed notifications functionality with f.e. Common script.


8. Miscellaneous.

This part controls all settings related to device connections to servers.

Category

Subcategory

Description

Category

Subcategory

Description

Fuel level averaging

Averaging state

Enables additional CAN fuel level approximation

Crash detection

Crash detection settings

Setting to trigger an impact notification (IN15) based on G powers and time

Event logging

Device event logging

Enable/disable of debug messages (events) send

Tachograph settings

Text data requests

Lets to create additional text data requests from tachograph (do not forget to add parameters to “Data recording”

DDD file settings

Let’s to set count of days in DDD file

Numeric data requests

Lets to create additional numeric data requests from tachograph (do not forget to add parameters to “Data recording”

Tacho file server

Here you need to set authentication and DDD file download addresses

Virtual input voltage threshold

IN8

Let’s to set from which voltage will IN8 (power detection) get On

Function keys

Function access keys

Function key to unlock device access to ISOBUS line