LLS Fuel sensors script

LLS Fuel sensors script

Version

V1.0

Script name

BCE_MEAS_LLS-FUEL-Sensor-SCR-1_7

Last updated

2019-04-18

Revision information

Rev. 7

Sensor - data to publish to broker.

Settings - user configurable settings.

Operating principle.

Table 1. Sensor and settings descriptions.

Nr.

Sensor name

Type

description

1.

RS232/RS485

Settings

Communication port

2.

Sensor address

Settings

Address of sensor

3.

Frequency

Sensor

Frequency value in Hz

4.

Fuel level

Sensor

Relative fuel value

5.

Temperature

Sensor

Temperature value in Celsius



Configuration.

1. Assign script to Setting template.


2. Configure script settings.

After assigning a script, the Settings field will appear. Expand it to configure.

a) Main Settings.

Here you set to which interface will FLS be connected:

 

b) Parameters settings.

Here you can set address of sensor and assign data to certain parameters to send them to Monitoring server.

Note. After assignining data to parameters, do not forget to create the same sensors in “data recording” in order data to be sent to server. In above example, it is parameters: sensor16389, sensor16390, sensor16391.


3. Multiple sensor configuration.

When using RS485 interface, possible to connect up to 14 sensors configured to different addresses. You can add them by clicking “Add” button under “Parameters settings”.

RS485 data transmission speed is 19200 bps.