Eurosens Delta 2 script
Version | 1.0.0 |
Script name | fuel_eurosens_delta_1.0.0 |
Last updated | Nov 12, 2026 |
Revision information | Replaces BCE_MEAS_EUROSENS-DELTA-02-SCR-7_2 |
1. Description
The script reads up to two Eurosens Delta fuel flow meters connected to the device's RS232 or RS485 port. It saves each meter's fuel level, flow speed and status in device sensors you choose, and these are sent to your platform with the rest of the device data.
1.1 Features
Up to 2 meters on one port, told apart by their network address.
Fuel level, flow speed and status for each meter, each saved to a sensor of your choice. Readings you don't need can be switched off.
A clear error value when a meter stops answering, so a disconnected or faulty meter is easy to spot.
Everything is set up in XDM, with no changes to the script.
1.2 How it works
The device asks each meter for its readings in turn: about every 1.5 seconds with one meter, every 2 seconds with two.
When a meter answers, its readings are saved to the selected sensors exactly as the meter sends them. The device does not convert them.
If an answer arrives damaged, that meter's sensors are set to the error value 4294967295 straight away.
If a meter doesn't answer, its last readings are kept for a short while. After 10 unanswered requests in a row (about 15-20 seconds), its sensors show 4294967295 until it answers again.
2. Setting up
2.1 Meter
Give each meter its own network address, for example 1 and 2.
Set the meter's serial connection to 19200 baud, 8 data bits, no parity, 1 stop bit.
Connect the meter's RS485 (or RS232) wires to the device port of the same type. The meter's manual shows its wire colours.
2.2 XDM
In the device configuration, select the script
fuel_eurosens_delta_1.0.0. Its settings appear in the configuration.In Port, select the port the meters are connected to.
In Meters, add one row per meter (at most 2) and fill it in as described in section 3.
Save the configuration and send it to the device.
Check that the selected sensors show readings and not 4294967295.
3. Settings
Setting | Values | Description |
|---|---|---|
Port | RS232, RS485 | The device port the meters are connected to. Default: RS232. |
Address | 0-255 | The meter's network address, as set in the meter. Each meter needs its own. Default: 1. |
Fuel level | Sensor or None | Sensor for the meter's fuel level. Select None if not needed. |
Flow speed | Sensor or None | Sensor for the meter's flow speed. Select None if not needed. |
Status | Sensor or None | Sensor for the meter's status (see 4.1). Select None if not needed. |
The sensors offered are 32-bit user-defined sensors. See Sensor descriptions for reference.
4. Readings
Sensor | Meaning |
|---|---|
Fuel level | Relative fuel value, as reported by the meter. |
Flow speed | Fuel flow speed, as reported by the meter. |
Status | The meter's operating state, see 4.1. |
All three show 4294967295 when the meter doesn't answer or its answer is damaged.
4.1 Status
The status is the sum of the meter's active states:
Value | State |
|---|---|
1 | Idle run |
2 | Nominal mode |
4 | Overload |
8 | Cheating |
16 | Negative |
32 | Intervention |
For example, 2 means nominal mode, and 10 (2 + 8) means nominal mode and cheating.
5. Requirements and limitations
Device firmware ***_01_121 or later.
At most 2 meters, both on the same port, at 19200 baud.
6. Changes from BCE_MEAS_EUROSENS-DELTA-02-SCR-7_2
fuel_eurosens_delta_1.0.0 replaces the earlier script and uses the same settings. Configurations on the earlier script keep it until you select the new one. After switching, check the Port and Meters settings.
More reliable readings on a noisy line: leftover data from one reading no longer spoils the next.