LLS Fuel sensors script
Version | V1.0 |
Script name | BCE_MEAS_LLS-FUEL-Sensor-SCR-1_7 |
Last updated | 2019-04-18 |
Revision information | Rev. 7 |
Sensor - data to publish to broker.
Settings - user configurable settings.
Operating principle.
Table 1. Sensor and settings descriptions.
Nr. | Sensor name | Type | description |
1. | RS232/RS485 | Settings | Communication port |
2. | Sensor address | Settings | Address of sensor |
3. | Frequency | Sensor | Frequency value in Hz |
4. | Fuel level | Sensor | Relative fuel value |
5. | Temperature | Sensor | Temperature value in Celsius |
Configuration.
1. Assign script to Setting template.
2. Configure script settings.
After assigning a script, the Settings field will appear. Expand it to configure.
a) Main Settings.
Here you set to which interface will FLS be connected:
b) Parameters settings.
Here you can set address of sensor and assign data to certain parameters to send them to Monitoring server.
Note. After assignining data to parameters, do not forget to create the same sensors in “data recording” in order data to be sent to server. In above example, it is parameters: sensor16389, sensor16390, sensor16391.
3. Multiple sensor configuration.
When using RS485 interface, possible to connect up to 14 sensors configured to different addresses. You can add them by clicking “Add” button under “Parameters settings”.
RS485 data transmission speed is 19200 bps.