Eurosens Direct/Delta CAN script
Eurosens Direct/Delta CAN script description
Version | V1.1 |
Script name | BCE_MEAS_DeltaCANSCR8_1 |
Last updated | 2019-09-02 |
Revision information | No revision |
Script Description
Device waits for any CAN message, if message was received - checks if it’s a message carrying data, if not, then waiting for another CAN message, if yes, then a value is set to sensor which user has selected in settings template (inside FMSET).
Sensors values and settings definition:
Fuel consumed since flow meter power ON: Value in liters, resolution 0,5L
Fuel consumed (not resettable): Value in liters, resolution 0,5L
Fuel consumed since flow meter power ON - high resolution: Value in liters, resolution 0,001L
Fuel consumed (not resettable) - high resolution: Value in liters, resolution 0,001L
Instant fuel consumption: Value in liters per hour, resolution 0,05L/hour
Time of fuel flow: Value in hours, resolution 0,05H
Fuel temperature (supply line): Value in Celsius, resolution 1C
Configuration
Inside fmset it's possible to select CAN - BUS channel and onto which sensors it is possible to save values that has been received from Eurosens Direct/Delta CAN devices.
Connection
Direct CAN and Delta CAN connects similarly, the only difference is that Delta can needs Terminating resistor between CAN H and CAN L lines.
Eurosens Direct CAN connection:
Yellow Direct CAN wire connects with our orange CAN H wire
Green Direct CAN wire connects with our orange striped CAN L wire
Brown Direct CAN wire connects with common ground
Red wire connects with positive 12V
Eurosens Delta CAN connection:
Yellow Direct CAN wire connects with our orange CAN H wire
Green Direct CAN wire connects with our orange striped CAN L wire
Brown Direct CAN wire connects with common ground
Red wire connects with positive 12V
Terminating resistor (should be included in Delta CAN package) connects between CAN H and CAN L wires