GiCAM BLE
GiCAM BLE fuel level sensor uses BLE and is supported only on LX40 series
LX40 Series
LX41
LX42
LX43
LX44
LX45
1. Adjustments in Configuration
1.1. Adding Script
In configuration template ‘Script'->’Script1'->'Script' select ‘[BLE] Accessory Scanner V1.0’ script. When script is added script settings will appear below
1.2. Configuring Script Filters
In newly appeared settings ‘Script1@[BLE] Accessory Scanner V1.0’ select ‘Filter' section and click import presets.
In pop-up window select “GiCAM FLS” and all presets will be filled out.
Under all added filters for fuel level, remaining battery, temperature in section 'Filter' add MAC address of the sensor, it should be visible on the front of sensor.
It is important to notice that when setting multiple sensors all their default sensor values will be the same. When adding multiple sensors manually change 'Sensor' parameter under each section.
1.3. Displaying in Monitoring Platform
For more in depth configuration of device configuration visit Quick Set Up Of Configuration
For device to report sensor values to telemetry platform sensors needs to be included into telemetry payload.