GiCAM BLE

GiCAM BLE

image-20250609-054556.png

GiCAM BLE fuel level sensor uses BLE and is supported only on LX40 series

LX40 Series

  • LX41

  • LX42

  • LX43

  • LX44

  • LX45

 

 


1. Adjustments in Configuration

1.1. Adding Script

In configuration template ‘Script'->’Script1'->'Script' select ‘[BLE] Accessory Scanner V1.0’ script. When script is added script settings will appear below

image-20250609-052908.png

1.2. Configuring Script Filters

In newly appeared settings ‘Script1@[BLE] Accessory Scanner V1.0’ select ‘Filter' section and click import presets.

image-20250609-052955.png

In pop-up window select “GiCAM FLS” and all presets will be filled out.

image-20250609-054738.png

Under all added filters for fuel level, remaining battery, temperature in section 'Filter' add MAC address of the sensor, it should be visible on the front of sensor.

image-20250609-054919.png

It is important to notice that when setting multiple sensors all their default sensor values will be the same. When adding multiple sensors manually change 'Sensor' parameter under each section.

image-20250609-054955.png

1.3. Displaying in Monitoring Platform

For more in depth configuration of device configuration visit Quick Set Up Of Configuration

For device to report sensor values to telemetry platform sensors needs to be included into telemetry payload.

image-20250609-055044.png