ELA MAG Door Sensor
ELA MAG door sensor uses BLE and is supported only on LX40 series
LX40 Series
LX41
LX42
LX43
LX44
LX45
1. Adjustments in Configuration
1.1. Adding Script
In configuration template ‘Script'->’Script1'->'Script' select ‘[BLE] ELA MAG BEACON V1.1’ script. When script is added script settings will appear below
1.2. Configuring Script Peripheral Settings
In ‘Filter type’ select ‘Name filter' fill out device name as written on ELA MAG device, for example - 'P MAG C037C1'.
For ‘MAG sensor state', ‘MAG sensor event counter’, ‘MAG sensor rssi’ select desired sensors where values will be saved, take note of selected sensors.
For this example we choose:
MAG sensor state- sensor 31
MAG sensor event counter - sensor 12301
MAG sensor rssi - sensor 24576
1.3. Displaying in Monitoring Platform
For more in depth configuration of device configuration visit Quick Set Up Of Configuration
For device to report sensor values to telemetry platform sensor values needs to be included into telemetry payload.
2. ELA MAG Documentation
Official documentation containing technical specifications, calibration and configuration info of ELA MAG door sensor.