Eurosens Direct CAN
Eurosens Direct fuel level sensor is supported on Xirgo Global devices with CAN communication.
XG37 Series
XtCAN
Tacho
LX40 Series
LX44
LX45
XG47 Series
XG47 CAN
1. Physical Connection
Eurosens Direct CAN version wire color coding:
Yellow
Green
Brown
White
CAN H
CAN L
+V power
Ground
When wiring Eurosens flowmeters multiple sensors can be connected following same topology as bellow, connect all flowmeters CAN H lines with CAN H line of Xirgo Global unit and same CAN L, connect all lines with CAN L of the unit.
Important to note if connection is made straight from Xirgo Global unit to Eurosens Meter CONFIGURE 120ohm resistor in meter settings. For this enable “Terminator“ option in meter settings.
For more detail look into 3. Eurosens Meters Documentation
2. Adjustments in Configuration
2.1. Adding Script
In configuration template ‘Script'->’Script1'->'Script' select ‘BCE_MEAS_DeltaCANSCR8_3’ script. When script is added script settings will appear below. If script is not present in script list contact out support team.
2.2. Configuring Script Settings
In newly appeared tab ‘Fuel flow meter data read settings' select sensor values you want to be saved on desired user defined sensors. It is also important to select correct XG device CAN channel where meters was connected.
2.3. Displaying in Monitoring Platform
For more in depth configuration of device configuration visit Quick Set Up Of Configuration
For device to report sensor values to telemetry platform sensors needs to be included into telemetry payload.
3. Eurosens Meters Documentation
Official documentation containing technical specifications, calibration and configuration info of Eurosens Flow Meters.