Eurosens Delta

Eurosens Delta

image-20250526-075353.png

Eurosens Delta fuel level sensor is supported on Xirgo Global devices with RS485 communication.

 

 

 

XG37 Series

  • Light+

  • XtCAN

  • Tacho

LX40 Series

  • LX43

  • LX45

XG47 Series

  • XG47 RS232

  • XG47 CAN


1. Physical Connection

Eurosens Delta version wire color coding:

Yellow

Green

Brown

White

RS-485A

RS-485B

+V power

Ground

 

When wiring Eurosens Delta flowmeters multiple sensors can be connected following same topology as bellow, connect all flowmeters RS-485A lines with RS-485A line of Xirgo Global unit and same RS-485B, connect all lines with RS-485B of the unit.

For more details look into 3. Eurosens Meters Documentation

image-20250526-081034.png

 

image-20250526-082150.png

 


2. Adjustments in Configuration

2.1. Adding Script

In configuration template ‘Script'->’Script1'->'Script' select ‘BCE_MEAS_EUROSENS-DELTA-02-SCR-7_2’ script. When script is added script settings will appear below. If script is not present in script list contact out support team.

image-20250526-082807.png

2.2 Configuring Peripheral

In newly appeared ‘Communication' tab select 'RS485’

image-20250526-082853.png

2.3. Configuring Script Settings

In newly appeared tab ‘Fuel flow meter data read settings' select sensor values you want to be saved on desired user defined sensors. ‘Network Address’ by default is set to ‘1' both in LLS sensor and script configuration. When sensor is connected through RS485 when using single sensor ‘Network Address’ parameter doesn’t need to be changed. However if using multiple LLS sensors connected through RS485 'Network Address' needs to be changed to one that was configured in LLS sensor, more about sensor configuration read paragraph 3. Eurosens Meters Documentation.

For ‘Temperature, °C', ‘Relative level’, 'Frequency’ select desired sensors where values will be saved, take note of selected sensors.

For this example we choose:
Temperature - sensor 16389
Relative fuel level - sensor 16390
frequency - sensor 16391

image-20250526-083045.png

2.4. Displaying in Monitoring Platform

For more in depth configuration of device configuration visit Quick Set Up Of Configuration

For device to report sensor values to telemetry platform sensors needs to be included into telemetry payload.

image-20250526-083343.png

3. Eurosens Meters Documentation

Official documentation containing technical specifications, calibration and configuration info of Eurosens Flow Meters.