Output Control structures

Output Control structures

OUTPUT ID

OUTPUT DATA N bytes

OUTPUT ID

OUTPUT DATA N bytes

 

OUT1 (00h)

OUT2 (01h)

OUT3 (02h)

 

Form ID

DATA (little endian)

Description

 

00h (or 80h, 40h)

2 bytes duration in 10ms resolution

Turn off output in given duration from 10ms to 655s.

 

01h (or 81h, 41h)

2 bytes duration in 10ms resolution

Turn on output in given duration from 10ms to 655s.

 

03h (or 83h,43h)

2 bytes duration in 10ms resolution

Hazard lamps control signals for given duration from 10ms to 655s.

 

04h (or 84h,44h)

2 bytes duration in 10ms resolution

First impulse to OUT[N], after 1 sec delay impulse to OUT[N+1]

If most significant bit set in Form ID (80) together with output command S1 signal turns ON, (40) - S1 turns off.

 

Unlock (05h)

Lock (06h)

 

Form ID

DATA (little endian)

Description

 

0

0x5000

Unlock Doors

 

0

0x5001

Lock Doors

 

0

0x5002

Unblock Engine

 

0

0x5003

Block Engine

Data bytes example - lock doors: 05 followed by 00 01 50

 

S1 (0Ah)

S2 (0Bh)

 

Form ID

DATA (little endian)

Description

 

00h

2 byte

0x0055 turns on corresponding signal

0x0000 turns off corresponding signal

Control of internal static signals.

 

RS232 (1Eh)

 

Form ID

DATA (little endian)

Description

 

00h (9600 bps 1stop bit no parity)

max 250 bytes of raw data

Bytes to send to RS232

 

Tachograph remote download (32h)

 

Form ID

DATA (little endian)

Description

 

0

0x0001

Slot 1 card download

 

0

0x0002

Slot 2 card download

 

0

0x0004

VU memory download (activities)

 

0

0x0008

VU memory download (no activities)

 

1

0x0001

Slot 1 card download

 

 

0x0002

Slot 2 card download

 

 

0x0004

VU memory download (activities)

 

 

0x0008

VU memory download (no activities)

 

DataCold600

remote UCP file download (33h)

Form ID

DATA 4 bytes
(little endian)

DATA 4 bytes
(little endian)

Description

0

Period in seconds

No

Make ucp file with records from given period

1

Period Begin

Period End

Make ucp file from Period Begin to Period End

 

USSD message (34h)

 

Form ID

DATA (little endian)

Description

 

0

max 250 bytes of raw data

Bytes to send to USSD

 

CAN message

(35h)

Form ID

DATA0

DATA1-4

DATA5

DATA6-13

1-CAN1

2-CAN2

0-STD

1-EXT

ID

LEN

DATA[8]

 

Force create socket to Fmset

(36h)

Any

 

Change 1W temp sensor position (37h)

 

Form ID

DATA0

DATA1

 

 

0

0-3

Temperature position to change

0-3