Device inputs

Device inputs

FMS 500 series devices have physical and virtual inputs. Input configuration depends from device model.

Input: IN2/ADC4, IN5/ADC5 can be used as digital or analog input.
Input: IN3/OUT1, ADC3/OUT2 can be used as digital input or as negative output.


IN5 - designated input for vehicle ignition detection.
IN7 - state depends from main power supply voltage. ON signal is generated above 13.2V or 26.6V.

Input

Type

Meaning

Sensor

Value

Input

Type

Meaning

Sensor

Value

IN1

Virtual input

Motion detection

Sensor_SignalMotion (2)

0 - off; 1 - on

IN2

Physical input

IN2 input of device

Sensor_SignalIN2 (16)

0 - off; 1 - on

ADC4

Physical input

ADC4 input of device

Sensor_ADC4 (12290)

1mV per bit

IN3

Physical input

IN3 input of device

Sensor_SignalIN3 (17)

0 - off; 1 - on

OUT1

Physical output

Physical OUT1

Sensor_OUT1 (148)

0 - off; 1 - on

IN4

Physical input

IN4 input of device

Sensor_SignalIN4 (18)

0 - off; 1 - on

IN5

Physical input

IN5 input of device (ignition state)

Sensor_SignalIN5 (19)

0 - off; 1 - on

ADC5

Physical input

ADC5 input of device

Sensor_ADC5 (12289)

1mV per bit

IN7

Virtual input

Virtual engine state

Sensor_SignalIN7 (20)

0 - off; 1 - on

IN8

Virtual input

Main power supply status

Sensor_SignalIN8 (21)

0 - off; 1 - on

OUT2

Physical output

Physical OUT2

Sensor_OUT2 (149)

0 - off; 1 - on

ADC3

Physical input

ADC3 input of device

Sensor_ADC3 (12291)

1mV per bit

Virtual device parameters here.