Conditions

Conditions

States of conditions

Conditions can have 3 states:

Below is example of data send configuration. Meaning of configuration is: to send data every 30s when IN5 (Ignition) is active and send every 300s when IN5 is inactive.


Description of conditions

Condition

or

Parameter

 

 

Condition

or

Parameter

 

 

Reset

Reset of device happened

Reset of device did not happen

Modem on *

Modem is On / Acceleration, Braking, Cornering threshold reached

Modem is Off / Acceleration, Braking, Cornering threshold not reached

IN1 - motion

Motion or strong vibration is detected

No motion is detected

IN6

Any analog input (ADC) is active

All analog inputs are inactive

Timer3Threshold

Threshold of Timer 3 is reached

Threshold of Timer 3 is not reached

System time registered

N/A

N/A

Geozone inside

Device detects being inside geozone

Device is outside geozones

Poor GPS signal

GPS signal is weaker than described in 3.1 and 3.2 functions

GPS signal is strong

GSM jamming

GSM jamming detected 

No GSM jamming is detected

Roaming

Device is in Roaming

Device is connected to home network

GSM registered

Device is registered to GSM network

No GSM registration is detected

GPRS registered

Device is registered to GPRS network

No GPRS registration is detected

Internet active

Internet connection is active

No internet connection

Preferred operator active

Operator from Preferred operators' list is active

No preferred operators to register

GPS speed present

Speed threshold, set in 5.i function is reached

Speed is below 5.i function threshold

Wiegand present

Wiegand26 key is detected

Wiegand key is not attached

IN2

Input 2 is active

Input 2 is not active

IN3

Input 3 is active

Input 3 is not active

IN4

Input 4 is active

Input 4 is not active

IN5

Input 5 is active

Input 5 is not active

IN7 - engine on

Voltage above 13.2V or 26.6V is reached

Voltage is lower than running engine

IN8

Power supply is On

Power supply is absent

One hour tick

Signal ON every one hour for 10 min period

Signal OFF every one hour for 10 min period

Six hours tick?

Signal ON every six hours for 10 min period

Signal OFF every six hours for 10 min period

Stack size threshold reached

Stack size of data, described in 5.3 is reached

Stack size is not reached

Geozone inside geozone

Device detects being in 2 geozone at a time

Device is not in 2 geozones at a time

Timer4Threshold

Threshold of Timer 4 is reached

Threshold of Timer 4 is not reached

Static signal 1

Static signal 1, configured in 5.j function is present

Static signal 1 is not present

Static signal 2

Static signal 2, configured in 5.k function is present

Static signal 2 is not present

Timer1

Current time is in a range of Timer 1 ON

Current time is in a range of Timer 1 OFF

IbuttonPresent

iButton key is detected

iButton key is not attached

Timer2Threshold

Threshold of Timer 2 is reached 

Threshold of Timer 2 is not reached

*- For new version devices parameter Modem on activates when acceleration, cornering or braking threshold values are reached.