Wiegand26 RFID Reader 125kHz
Wiegand26 sensors is supported on Xirgo Global devices with at least two inputs. This is one of examples for one of many wiegand26 readers, all devices supporting wiegand26 protocol will work with Xirgo Global devices.
XG37 Series
Light
Light+
XtCAN
Tacho
LX40 Series
LX42
LX43
LX44
LX45
1. Physical Connection
IronLogic CP-Z 2L or CP-Z 2EP Sensor wire color coding:
Blue
White
Red
Black
Data1
Data0
+V power
Ground
Wiegand26 communication is set up on inputs IN2 and IN3.
Wiring examples:
2. Adjustments in Configuration
To configure device to work with Wiegand26 sensors in XDM configuration template under ‘Hardware'->’Wiegand26'->'Wiegand26 settings' enable ‘Wiegand26 function'
Then go to ‘Hardware'->’Digital inputs threshold'->'Inputs threshold settings' and set voltage threshold to around 3V
3. Displaying in Monitoring Platform
For more in depth configuration of device configuration visit Quick Set Up Of Configuration
To configure device to send Wiegand26 sensor parameters to telemetry server following sensors needs to be added to payload:
SENSOR_ID_WIEGAND_26 (16481)
SENSOR_SIGNAL_WIEGAND_ID_PRESENT (15)
4. Documentation
Official documentation.