Accessory Scanner Supported Integrations
Manufacturer | Model | Preset name | Supported parameters | Notes |
|---|---|---|---|---|
Blue PUCK T Blue COIN T Blue PUCK RHT | ELA Temperature |
| Instructions: Enter the full beacon name and select a sensor. Note: Use beacons that advertise service data frame type. Raw temperature value must be divided by 100 to get the correct float value. | |
Blue PUCK MAG Blue COIN MAG | ELA MAG |
| Instructions: Enter the full beacon name and select a sensor. Counter value must be shifted to the right by 1 bit. Note: Use beacons that advertise service data frame type. | |
Blue PUCK RHT | ELA RHT |
| Instructions: Enter the full beacon name and select a sensor. Note: Use beacons that advertise service data frame type. Raw temperature value must be divided by 100 to get the correct float value. | |
TD-BLE | Escort TD-BLE |
| Instructions: Enter the MAC address between the colon characters. Battery voltage raw value must be divided by 10. Note: Fuel level calculations must be done on the server side | |
Degree BT | Eurosens Degree BT |
| Instructions: Enter the MAC address between the colon characters. | |
Eurosens Degree BT Drum rotation mode |
| |||
Eurosens Degree BT Excavator mode |
| |||
Dominator BT | Dominator BT sensors |
| Instructions: Enter the MAC address between the colon characters. | |
BLE FLS | GiCAM FLS |
| Instructions: Enter the MAC address between the colon characters. Note: Read the manufacturer supplied documentation on how to interpret the raw fuel level value. | |
Sentrius BT510 | Laird Sentrius BT510 |
| Instructions: Enter the MAC address of the sensor between the colon characters. Mac address also needs to be entered in the pattern match field with a different endianess. Do not change the last two characters as they are used to differentiate between the Bluetooth packets. Only change X1, X2, ..., X6. For example: | |
DUT-E S7 | DUT-E S7 |
| Instructions: Enter the MAC address between the colon characters. Temperature has an offset of "-50". Fuel frequency raw value must be multiplied by 0.001. Note: Calculations on the server side are needed to convert fuel frequency to fuel level. | |
Eye beacon | Teltonika eye beacon (sensors + ID) |
| Instructions: Enter the MAC address between the colon characters. Temperature raw value must be multiplied by 0.01. Magnet status must be shifted by 7 bits to the right. Battery voltage must be multiplied by 10 and 2000 offset is to be added. Note: For this filter to work, all sensors on the Teltonika eye beacon must be turned on. “Teltonika eye beacon (sensors)” preset will not work when ID (Eddystone, iBeacon or Teltonika ID format) is advertised. | |
Teltonika eye beacon (sensors) | ||||
TSDT1-B | TopFly DS |
| Instructions: Enter the MAC address between the colon characters. Temperature raw value must be multiplied by 0.01. | |
TSTH1-B | TopFly T&H |
| Instructions: Enter the MAC address between the colon characters. Temperature raw value must be multiplied by 0.01. | |
Smart Fuel Cap | TrakfuelCap |
| Instructions: Enter the MAC address between the colon characters. | |
XT10 | Xirgo XT10 (Door state) |
| Instructions: For example: Door sensor state data must be shifted to the right by 6 bits. |
Note: Presets, supported parameters and instructions are subject to change.