Accessory Scanner Supported Integrations

Accessory Scanner Supported Integrations

Manufacturer

Model

Preset name

Supported parameters

Notes

Manufacturer

Model

Preset name

Supported parameters

Notes

ELA

Blue PUCK T

Blue COIN T

Blue PUCK RHT

ELA Temperature

  • Temperature

Instructions: Enter the full beacon name and select a sensor.

Note: Use beacons that advertise service data frame type.

Raw temperature value must be divided by 100 to get the correct float value.

Blue PUCK MAG

Blue COIN MAG

ELA MAG

  • Status

  • Counter

Instructions: Enter the full beacon name and select a sensor.

Counter value must be shifted to the right by 1 bit.

Note: Use beacons that advertise service data frame type.

Blue PUCK RHT

ELA RHT

  • Temperature

  • Humidity

Instructions: Enter the full beacon name and select a sensor.

Note: Use beacons that advertise service data frame type.

Raw temperature value must be divided by 100 to get the correct float value.

Escort

TD-BLE

Escort TD-BLE

  • Fuel level (RAW)

  • Battery voltage

  • Temperature

Instructions: Enter the MAC address between the colon characters.

Battery voltage raw value must be divided by 10.

Note: Fuel level calculations must be done on the server side

Eurosens

Degree BT

Eurosens Degree BT

  • X angle

  • Y angle

  • Z angle

  • Status

  • Temperature

Instructions: Enter the MAC address between the colon characters.

Eurosens Degree BT Drum rotation mode

  • Drum rotation speed

  • Y angle

  • Z angle

  • Status

  • Temperature

  • Total drum rotation time

  • Number of drum starts

Eurosens Degree BT Excavator mode

  • X angle

  • Y angle

  • Z angle

  • Status

  • Temperature

  • Status of operation

  • Total time of operation

Dominator BT

Dominator BT sensors

  • Battery charge

  • Temperature (1 ° C / bit) (-40)

  • % of fuel from a full tank

  • Fuel volume

  • Detector value

Instructions: Enter the MAC address between the colon characters.

GiCAM

BLE FLS

GiCAM FLS

  • Fuel level (RAW)

  • Remaining battery life in months

  • Temperature

Instructions: Enter the MAC address between the colon characters.

Note: Read the manufacturer supplied documentation on how to interpret the raw fuel level value.

Laird/Ezurio

Sentrius BT510

Laird Sentrius BT510

  • Temperature

  • Magnet state

  • Battery voltage

  • Reset reason

  • Flags

Instructions: Enter the MAC address of the sensor between the colon characters. Mac address also needs to be entered in the pattern match field with a different endianess. Do not change the last two characters as they are used to differentiate between the Bluetooth packets. Only change X1, X2, ..., X6.

For example:
Filter: E6:37:A5:27:FC:22
Pattern match field: 22FC27A537E601 (for temperature filter)

Technoton

DUT-E S7

DUT-E S7

  • Fuel frequency

  • Temperature

Instructions: Enter the MAC address between the colon characters.

Temperature has an offset of "-50".

Fuel frequency raw value must be multiplied by 0.001.

Note: Calculations on the server side are needed to convert fuel frequency to fuel level.

Teltonika

Eye beacon

Teltonika eye beacon (sensors + ID)

  • Temperature

  • Humidity

  • Magnet status

  • Magnet counter

  • Pitch

  • Roll

  • Battery voltage

Instructions: Enter the MAC address between the colon characters.

Temperature raw value must be multiplied by 0.01.

Magnet status must be shifted by 7 bits to the right.

Battery voltage must be multiplied by 10 and 2000 offset is to be added.

Note: For this filter to work, all sensors on the Teltonika eye beacon must be turned on. “Teltonika eye beacon (sensors)” preset will not work when ID (Eddystone, iBeacon or Teltonika ID format) is advertised.

Teltonika eye beacon (sensors)

TOPFLYtech

TSDT1-B

TopFly DS

  • Door status

  • Alarm

  • Temperature

  • Battery voltage

Instructions: Enter the MAC address between the colon characters.

Temperature raw value must be multiplied by 0.01.

TSTH1-B

TopFly T&H

  • Temperature

  • Humidity

  • Light sensor

Instructions: Enter the MAC address between the colon characters.

Temperature raw value must be multiplied by 0.01.

Trak

Smart Fuel Cap

TrakfuelCap

  • Detachment flag

  • Unlock flag

  • Detachment event flag

  • Attachment event flag

  • Rotation event flag

  • Coupling flag

  • Battery percentage

  • Temperature

  • Lock byte

  • Rotation byte

Instructions: Enter the MAC address between the colon characters.

Xirgo

XT10

Xirgo XT10 (Door state)

  • Door state

Instructions:
Enter EUID in little-endian format in the pattern match field. Only change X1, X2, ..., X6 values.

For example:
EUID: E6:37:A5:27:FC:22
Pattern match field: 22FC27A537E63C04 (for door state)

Door sensor state data must be shifted to the right by 6 bits.

Note: Presets, supported parameters and instructions are subject to change.