ThermoKing script

ThermoKing script

Version

V1.0

Script name

BCE_MEAS_Thermoking-SCR10_4

Last updated

2019-04-16

Revision information

No revision

Sensor - data to publish to broker.

Settings - user configurable settings.

 

Operating principle

Device every 10 seconds reads new values from Thermoking device. If There is no answer 4 times in a row then error code: 1111 1111 instead of temperature value.

 

Table 1. Sensor and settings descriptions.

Nr.

Sensor name

type

Data meaning

1.

Temperature

Sensor

Value in Celsius

 

Configuration

Configuration is done via FMSET. In BCE_MEAS_Thermokng-SRC10_1 settings 6 temperature sensors could be configured. To turn off sensors reading and publishing then switch Temperature value to None as shown in image 1. To change temperature publish time change GPS timeout as shown image 2.

Image 1. Sensors configuration via FMSET.

Image 2. Publish time configuration via FMSET.

 

Connection

Image 3. Connection between FMS500 XtCan and TouchPrint device RS232 ports.