Sensor Description
Sensor ID | Sensor Name | Sensor Description |
|---|---|---|
|
| Boolean sensors |
0 | - | - |
1 | SENSOR_MODEM_ON | Status of cell module on board |
2 | SENSOR_MOTION_DETECTED | Source: Accelerometer. Start: instantly. Reset: delayed |
3 | - | - |
4 | - | - |
5 | SENSOR_SYSTEM_TIME_PRESENT | Status to indicate whether system has a valid time |
6 | SENSOR_INSIDE_GEOZONE | Status to indicate whether device is currently inside geozone |
7 | SENSOR_POOR_GNSS_SIGNAL | Set when device has GNSS fix but Satellite count and HDOP is low |
8 | SENSOR_GSM_JAMMING | Status to indicate whether cellular connectivity is currently being jammed |
9 | SENSOR_ROAMING | Status to indicate whether cellular connectivity is currently in roaming mode |
10 | SENSOR_GSM_REGISTERED | Status to indicate device registration to cellular network |
11 | SENSOR_GPRS_REGISTERED | Status to indicate if GPRS service is currently available |
12 | SENSOR_PDP_ACTIVE | Status to indicate that device has currently active internet session (PDP) |
13 | SENSOR_PREFERRED_OPERATOR_ACTIVE | Status to indicate whether device is currently attached to preferred operator (only active if operator list is assigned in settings) |
14 | SENSOR_GNSS_SPEED_PRESENT | Status to indicate that speed value from GNSS receiver is above 0. |
15 | SENSOR_SIGNAL_WIEGAND_ID_PRESENT | Status to indicate that card ID value has been read using Wiegand26 protocol. 4 second reset delay after removing id |
16 | SENSOR_IN_2 | Status to indicate that IN2 has voltage above value configured through digital inputs threshold setting. |
17 | SENSOR_IN_3 | Status to indicate that IN3 has voltage above value configured through digital inputs threshold setting. |
18 | SENSOR_IN_4 | Status to indicate that IN4 has voltage above value configured through digital inputs threshold setting. |
19 | SENSOR_IN_5 | Status to indicate that IN5 has voltage above value configured through digital inputs threshold setting. |
20 | SENSOR_IN_7 | Status to indicate alternator voltage (virtual ignition) through power rail. 30 seconds to become 1 from 0. instantly from 0 to 1. threshold=13.2V |
21 | SENSOR_IN_8 | Status to indicate that selected ADC channel is above threshold set in the settings |
22 | SENSOR_ONE_HOUR_TICK | Set for 3 minutes every hour |
23 | SENSOR_SIX_HOURS_TICK | Set for 3 minutes every 6 hours |
24 | - | - |
25 | - | - |
26 | - | - |
27 | SENSOR_STATIC_SIGNAL_1 | Signal that persists it’s value even after software reset. Can be controlled with TCP and SMS commands over the air or using scripts to control device functions |
28 | SENSOR_STATIC_SIGNAL_2 | Signal that persists it’s value even after software reset. Can be controlled with TCP and SMS commands over the air or using scripts to control device functions |
29 | - | - |
30 | SENSOR_IBUTTON_PRESENT | Status to indicate when Ibutton tag has been read using 1 wire. 4 second reset delay after removing id |
31 | SENSOR_BOOL_USER_DEFINED_0 | Boolean type sensor to store custom values using scripts |
32 | SENSOR_BOOL_USER_DEFINED_1 | Boolean type sensor to store custom values using scripts |
33 | SENSOR_BOOL_USER_DEFINED_2 | Boolean type sensor to store custom values using scripts |
34 | SENSOR_BOOL_USER_DEFINED_3 | Boolean type sensor to store custom values using scripts |