Sensor - data to publish to broker.
Settings - user configurable settings.
Operating principle
Table 1. Sensors and settings description
Nr. | Sensor name: | type | Data meaning: |
1. | Humidity sensor ID | Settings | ID of device address |
2. | Temperature sensor ID | Settings | ID of device address |
3. | Temperature value sensor | Sensor | Temperature value in Celsius |
4. | Humidity value sensor | Sensor | Humidity value in percent’s |
Connection
Image 1. Connection between FMS500 XtCan and AM2105A devices RS485 ports.
Version | V1.0 |
Author | Giedrius Pupeikis |
Script name | BCE_MEAS_AM2105A-SCR50 tool to change address |
Last updated | 2019-12-03 |
Revision information | No revision |
Principle of operation
Stage 1: Device LED blinks very slow. This stage means that device is searching connected sensor.
To correctly connect sensor: connect ground wire, then connect both RS485 wires and then connect power wire.
Stage 2: Device LED blinks very fast. Device waits for pressed button in this stage. There are three buttons. Button 1 set device address to 0x21 and 0x26; Button 2 set device address to 0x22 and 0x27; Button 3 set device address to 0x23 and 0x28.
Stage 3: Device LED blinks slow. Device tries to change sensor address.
Stage 4: Device LED is turned on always. This means that address changed successfully.
To correctly disconnect sensor: disconnect power, then disconnect both RS485 wires and then disconnect ground wire.
Then device goes to stage 1.
Process again with another sensor in same order.
Connection
Figure 2. Tool connection for address changing on XtCan device