AM2105A script

AM2105A script

This content is archived.

Version

V1.0

Author

Giedrius Pupeikis

Script name

BCE_MEAS_AM2105A-SCR-50

Last updated

2019-09-04

Revision information

No revision

Sensor - data to publish to broker.

Settings - user configurable settings.

 

Operating principle

Table 1. Sensors and settings description

Nr.

Sensor name:

type

Data meaning:

1.

Humidity sensor ID

Settings

ID of device address

2.

Temperature sensor ID

Settings

ID of device address

3.

Temperature value sensor

Sensor

Temperature value in Celsius

4.

Humidity value sensor

Sensor

Humidity value in percent’s

 

Connection

Image 1. Connection between FMS500 XtCan and AM2105A devices RS485 ports.

 

Version

V1.0

Author

Giedrius Pupeikis

Script name

BCE_MEAS_AM2105A-SCR50 tool to change address

Last updated

2019-12-03

Revision information

No revision

 

Principle of operation

 

Stage 1: Device LED blinks very slow. This stage means that device is searching connected sensor.

To correctly connect sensor: connect ground wire, then connect both RS485 wires and then connect power wire.

 

Stage 2: Device LED blinks very fast. Device waits for pressed button in this stage. There are three buttons. Button 1 set device address to 0x21 and 0x26; Button 2 set device address to 0x22 and 0x27; Button 3 set device address to 0x23 and 0x28.

 

Stage 3: Device LED blinks slow. Device tries to change sensor address.

 

Stage 4: Device LED is turned on always. This means that address changed successfully.

To correctly disconnect sensor: disconnect power, then disconnect both RS485 wires and then disconnect ground wire.

 

Then device goes to stage 1.

 

Process again with another sensor in same order.

 

Connection

Figure 2. Tool connection for address changing on XtCan device